Get the Guide to The “Designing for Compliance” Series Hazard #1 – Preventing electrical shock to the user

Learn more about The “Designing for Compliance” Series Hazard #1 – Preventing electrical shock to the user from our expert product safety testing, certification, and regulatory compliance team here at CertifiGroup.

This whitepaper will cover:

Important product safety testing, certification, and regulatory expertise from our team here at CertifiGroup

Fill out the form below to gain access to the white paper immediately.

Thank you for your submission, the requested weekly whitepaper is now available below.

Weekly Whitepaper
Week #30

The 6 Hazards of Product Safety – Risk of Shock

The “Designing for Compliance” Series Hazard #1 – Preventing electrical shock to the user

“Designing for Compliance” is critical to getting your product certified on the first try. Designing for Compliancerequires owning, knowing, and applying the standard(s) while designing your product. However, in order to
successfully read and understand the standard, you have to know the intent of the requirements. Our “Designing
for Compliance” series of whitepapers will educate you on “The 6 Hazards of Product Safety”. The intent of the
requirements in all UL/CSA/EN/IEC safety standards is to protect the user from the “6 Hazards of Product
Safety”. This whitepaper covers Hazard #1 – Risk of Shock.

Risk of Shock Definition: A “Risk of Shock” is considered to exist within a product if the user can access a
hazardous voltage circuit (typically >30VAC). Due to the potential for severe injury or death from an electrical
shock, two levels of protection are required from circuits presenting a shock hazard. Two levels of protection
means that even when one protection method goes bad (referred to as a single fault condition) the user still
cannot be shocked.

Risk of Shock – Level of Importance: The most important requirement in the product safety standards is to protect
the user from receiving an electric shock. And, because the outcome from an electric shock can be so severe
(potential for death), the product safety standards require that you provide “2 Levels” of protection from a potential
shock hazard. And it’s that “2nd level” that results in much of the difficulty in understanding how to design for
shock hazard compliance. It is also part of the reason that Risk of Shock protection accounts for more than 50%
of the requirements and tests in most UL standards. So if you learn Risk of Shock, you have learned a large part
of the standard.

Risk of Shock – Accessibility: The first element of learning Risk of Shock protection is to understand the term
“accessibility”. In order for the user to get “shocked”, the user must touch an electrical circuit. Ability to touch an
electrical circuit is typically referred to as “accessibility”. This is critical to understanding Risk of Shock and it
provides us with the first set of important compliance design questions:

  1. Can the user access the circuit?

  2. Do you need the user to access the circuit?

To answer these questions we need the product safety standards. Product safety is not intended to be a
subjective process. Determining whether the user can access the circuit should not be dependent on whose
finger is used. Rather, the product safety standards specify “accessibility probes” that are used to determine
what circuits are considered to be user accessible. There are different accessibility probes in different standards.

Many compliance professionals are familiar with the “International Finger” which is based on an adult male hand
size. There is also a “UL Finger” that is much smaller as it is based on the hand size of a women and, a set of
“Child Finger Probes” representing two different age groups of children, with the probe including a child’s arm.
In addition, some standards include probes that represent a basic tool that is typically found in the product’s user
environment (paper clip, screw driver, etc.). There is even a test chain that simulates a user’s jewelry drooping
into a product vent to see if it can “access” a hazardous circuit. Be sure to check your product safety standards
to identify what accessibility probes and conditions of use apply to your products (i.e. force limitations, limited
use guidelines, etc.).

It should be noted that most safety standards require opening and removing all parts that can be removed or
opened without tools before applying the accessibility probes. This can include using a Finger Nail probe to try
and pry open snapped together parts. And for products with electrical connectors for communication or
accessories (USB, headphones, etc.), these connectors are assumed to be accessible regardless of the type of
connector. This is very important – all circuits connected to external connectors are usually considered user
accessible (other than certified power receptacles).

Risk of Shock – Shock Hazard Levels: Once you identify all circuits that can be “accessed” by the probes, the
next step is for you to answer the question “do you need for the user to access the circuit”? If the answer is no,
you should design means into the product to prevent the accessibility probes from accessing the circuit (locking
door, screw down a panel, replace thumbscrews, change a vent size or location, etc.). However, you may need
the user to be able to access the circuit (usb port, headphone jack, change battery, plug-in options, etc.). Circuits
which are accessible must not be a “Shock Hazard”. For an accessible circuit, the first step in verifying
compliance is to determine if the accessible circuit is at a “Shock Hazard Level”.

Each product safety standard defines a Shock Hazard level circuit. This definition always begins with a definition
for “hazardous voltage level”. In many standards, voltages above 30 Vrms are considered a shock hazard. Some
standards expand that definition to 30Vrms, 42.4 Vpk or 60VDC. These numbers can vary by standard, so be
sure of the limits in your standard. Also be aware that for some standards such as the standard for electrical
medical products, the accessible voltage limit is lower (25 Vrms).

Risk of Shock – 2 Levels of Protection: Once you know which circuits are user accessible, and you have verified
they are not at shock hazard voltage level, you must verify that the accessible circuit is properly protected during
fault conditions. The product safety standards require that you must protect the user from all potential shock
hazards with 2 levels of protection (“2 levels”, not “2 layers”). Two levels of protection means that if the user is
touching the circuit, and a fault occurs, the user still will not be shocked (the voltage in the accessible circuit will
not increase above the hazardous voltage limits). The standards accomplish this by requiring “Double” or
“Reinforced Insulation” between accessible circuits and all hazardous voltage circuits. For double and reinforced
insulation, a single fault will not eliminate the insulation.

Double or reinforced insulation can only be achieved through the use of an isolation device = meaning that you
must have an isolation transformer or opto-isolator between the accessible circuit and all mains/hazardous
voltage circuits. This can be a very complex process, insuring that each isolation device has 2 “levels” of
insulation, and that each of the 2 levels protects in the event that 1 fails. Which is the reason Risk of Shock is
such a large part of the product safety standards.

Risk of Shock – Summary: In summary, “accessible circuits” are those circuits that can be contacted by the
accessibility probes. Users must be protected from a Risk of Shock. To do this, all accessible circuits must be
verified to have 2 levels of protection from shock hazards. Shock hazard circuits include all interconnected
circuits that contain a hazardous voltage (30Vrms, 42.4Vpk, 60VDC). Accessible circuits must be “isolated” from
all hazardous voltage circuits by 2 levels of protection = double or reinforced insulation. Primarily, shock hazard
protection involves verifying the product has 2 levels of protection between all accessible parts/circuits and all
hazardous voltage circuits, and that each level of protection meets the requirements within the standard.

Compliance Assistance Services to help you get it right the 1st time
Preliminary Design Reviews, Design Guidance, Training
US, Canadian, CE, & International Certifications

CertifiGroup.com

Experts in UL, CSA, CE, & International Regulatory Compliance

©2014-2020 CertifiGroup – complete copies of this document may be freely distributed

Contact Inquiry Form

Fill out the form below and we’ll get back to you in 2-3 business days.

How would you like to get in touch?

Please select a preferred method of contact.

Direct Phone Line

Call and talk with a human, available 8:30 AM-4:30 PM Monday-Friday.

Contact Inquiry Form

Write us about your next project.

Available 24/7 365 days per year.